Test and Adjustment 8-11
D-H023.0906EN
innovators in agriculture
8.7 Cleaning Systems
8.7.1 Test the Spray Beam of the Teat Disinfection Nozzle
Test
1. Select:
• Tab [Test]
• [Test menu]
• [Mothership]
• [Other]
• Disinfection nozzle [On].
2. Make sure the spray beam (1, fig. 65,
page 8-11) is cone-shaped and
provides a full spray pattern.
3. Select Disinfection nozzle [Off].
4. If necessary, clean the teat disinfection nozzle or replace the teat
disinfection nozzle.
Figure 65. Test the spray beam
8.7.2 Test the Spray Beam of the Disinfection Nozzle for the Cleaning Brushes
Test
1. Select:
• Tab [Test]
• [Cleaning]
• [Pre treatment].
2. In the field Brush cleaning, select [On].
3. Make sure the spray beam is cone-shaped, provides a full spray
pattern and fully cover the cleaning brushes.