5-2 Installation
D-H023.0906EN
innovators in agriculture
3. Disconnect the CAN-bus connector (7) from the milking robot.
4. Remove the nut, washer and bolt (3, fig. 16,
page 5-5) from the strip
(2) and the processor installation bracket (4).
5. Remove the processor (5) from the processor installation bracket.
CAUTION
Make sure no debris can enter the tubes and the electrical connector(s).
6. Clean the outside of the processor and the tubes and cables.
7. Put the processor on a clean and safe place.
Adjust
1. De-register the MQC-C on the milking robot (X-Link) and in the T4C
software.
Close-up
1. Open the ball valve (1, fig. 14,
page 5-4)
2. Install the middle and the lower cover. (page 7-6)
3. Close the multiple function box (page 7-11).
4. Put the milking robot in operation with the X-Link (page 6-1).
5.1.2 Installation of the Processor and the Sampler
Preparation
CAUTION
Before you install the processor and the sampler, you must do a short rinse.
1. Do a short rinse with the X-link.
2. Take the milking robot out of operation with the X-Link (page 6-1).
3. Open the multiple function box (page 7-11).
4. Remove the middle and the lower cover (page 7-6).
5. Close the ball valve (1, fig. 14,
page 5-4).
Install the processor
CAUTION
Make sure no debris can enter the tubes and the electrical connector(s).
1. Install the processor (5, fig. 16, page 5-5) on the processor
installation bracket.
2. Install the nut, washer and bolt (3, fig. 16,
page 5-5) on the strip (2)
and the processor installation bracket (4).
3. Connect the CAN-bus connector (7) on the milking robot.