EasyManua.ls Logo

LELY ASTRONAUT A3 Next - Udders Not Clean Before Milking; Cleaning Brushes Are Dry; X-Link is OFF; Alarm System Does Not Generate Phone Call During Night

LELY ASTRONAUT A3 Next
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-2 Troubleshooting
D-H023.0906EN
innovators in agriculture
3. If the problem remains:
1. Make sure the cubicles and the passages are clean.
2. Make sure the cow's udders are shaved and the tails are cut
(page 6-4).
9.5 The Udders are not clean before the Milking starts
1. Make sure the brushes are clean after brush cleaning (page 9-1).
2. Make sure the cubicles and the passages are clean.
3. Make sure the cow's udders are shaved and the tails are cut (page
6-4).
4. Use more litter in the barn.
5. Increase the quantity of pre-treatments until the udders are clean.
6. Reset the quantity of pre-treatments to the default value (2).
9.6 Cleaning Brushes are dry
Note:
This occurs when the cleaning process is disturbed.
1. Make sure the water supply is ON.
2. Restart the robot with the option 'Empty boiler' (page 6-2).
9.7 X-Link is OFF
1. Make sure the main power supply is ON and the fuses are not
blown.
2. Make sure the power supply is ON (page 7-4).
3. Make sure the circuit breakers are ON (page 7-4).
4. If the problem remains, call your local Lely service provider.
9.8 Alarm System does not generate a Phone Call during the
Night
1. Make sure the telephone system is functioning correctly.
2. Make sure there are no active alarms (page 6-17).
3. Make sure the alarm system settings are correct (page 8-14).
4. Test the alarm on the CRS+ (page 4-46).

Table of Contents

Related product manuals