4-40 Description and Operation
D-H023.0906EN
innovators in agriculture
Button/Indicator Description
ENTER To confirm options and entries.
Note:
If the menu is longer than can be displayed an arrow up or down is displayed.
If there is a submenu a right arrow is displayed.
Start Up and Main Menu
During Start Up
If you start up the system, the display shows the startup screen:
Software version
: 00:65
System check
: OK
Number connected robots
: 1 (2)
[201] 101 102
Explanation:
Line 1 shows the version of the CRS+ software version used.
Line 2 shows "
System check", followed by:
OK: no error occurred during start up.
MOD :a modem error occurred during start up.
SPC: a speech card error occurred during start up.
Note:
Please call your service provider if this line displays
MOD or SPC.
Line 3 shows the number of connected robots. In the examples 1 of 2
robots (101 and 102) were found.
Line 4 shows the software address of the CRS+ followed by the
software addresses of the robots.
After about 5 minutes the status screen appears:
Destination milk/water
: main tank
State main cleaning
: standby
State precooler
: standby
Number of active alarms
: 0 15:35
Line 1 shows Destination milk/water:
main tank
Sewer
buffertank.
Line 2 shows
State main cleaning, for instance:
standby
Main cleaning.
Line 3 shows
State precooler:
standby/emptying or cluster operation: out oper.
Line 4 shows
Number of active alarms, and the current time.