9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
Implemented CANopen objects
160 L EDS94ARNExxxx EN 2.3 - 06/2014
I-1206
Identifier setting for SDO server channel 7. For description see object I-1201.
I-1207
Identifier setting for SDO server channel 8. For description see object I-1201.
I-1208
Identifier setting for SDO server channel 9. For description see object I-1201.
I-1209
Identifier setting for SDO server channel 10. For description see object I-1201.
Index:
I-1206
Name:
SDO7 server parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Highest subindex supported 3 - (read access only) ro U8
1: COB-ID client -> server (rx) 0x80000000 0 4294967295 rw U32
2: COB-ID server -> client (tx) 0x80000000 0 4294967295 rw U32
3: Node ID of the SDO client 1 ... 127 - (read access only) ro U32
Index:
I-1207
Name:
SDO8 server parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Highest subindex supported 3 - (read access only) ro U8
1: COB-ID client -> server (rx) 0x80000000 0 4294967295 rw U32
2: COB-ID server -> client (tx) 0x80000000 0 4294967295 rw U32
3: Node ID of the SDO client 1 ... 127 - (read access only) ro U32
Index:
I-1208
Name:
SDO9 server parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Highest subindex supported 3 - (read access only) ro U8
1: COB-ID client -> server (rx) 0x80000000 0 4294967295 rw U32
2: COB-ID server -> client (tx) 0x80000000 0 4294967295 rw U32
3: Node ID of the SDO client 1 ... 127 - (read access only) ro U32
Index:
I-1209
Name:
SDO10 server parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Highest subindex supported 3 - (read access only) ro U8
1: COB-ID client -> server (rx) 0x80000000 0 4294967295 rw U32
2: COB-ID server -> client (tx) 0x80000000 0 4294967295 rw U32