EasyManua.ls Logo

Lenze L-force 9400 Series

Lenze L-force 9400 Series
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
200 L EDS94ARNExxxx EN 2.3 - 06/2014
8.6.1.3 Module ID
The module ID serves to identify the module in which the error has occurred.
The following table lists the module ID in hexadecimal format:
Module ID Module
hex decimal
0x0065 101 Logbook module
0x0068 104 Module identification
0x0069 105 Error check of the program memory during runtime
0x006a 106 Runtime environment for IEC 61131-3 programs
0x006e 110 Supply voltage monitoring
0x006f 111 Monitoring of the 24 V supply voltage
0x0072 114 Service register
0x0075 117 Device control
0x0077 119 Temperature monitoring
0x0078 120 Analog signal monitoring
0x0079 121 Control signal interface
0x007a 122 Processing of digital inputs/outputs
0x007b 123 Control
0x007c 124 Device command module (C00002
)
0x007d 125 Processing of analog inputs/outputs
0x007f 127 Interface for intelligent communication module
0x0083 131 "CAN on board": CAN dispatcher
0x0084 132 "CAN on board": CAN-NMT handler
0x0085 133 "CAN on board": CAN emergency handler
0x0086 134 "CAN on board": CAN-NMT master
0x0087 135 "CAN on board": CAN-PDO handler
0x0088 136 "CAN on board": CAN-SDO server
0x0089 137 "CAN on board": CAN-SDO client
0x008c 140 Application project manager
0x008e 142 Communication interface for internal communication
0x0090 144 Parameter manager
0x0091 145 Lenze runtime system
0x0092 146 Interface for safety module
0x0093 147 Sync signal generation
0x009d 157 CAN module in MXI1: CAN dispatcher
0x009e 158 CAN module in MXI1: CAN-NMT handler
0x009f 159 CAN module in MXI1: CAN emergency handler
0x00a0 160 CAN module in MXI1: CAN-NMT master
0x00a1 161 CAN module in MXI1: CAN-PDO handler
0x00a2 162 CAN module in MXI1: CAN-SDO server
0x00a3 163 CAN module in MXI1: CAN-SDO client
0x00ac 172 CAN module in MXI2: CAN dispatcher
Bit 31 1625262829 015