9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00166
286 L EDS94ARNExxxx EN 2.3 - 06/2014
C00166
C00167
C00168
C00169
C00171
Parameter | Name:
C00166 | Error description
Data type: VISIBLE_STRING
Index: 24409
d
= 5F59
h
Error description for the error number displayed in C00168
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00167 | Service code
Data type: VISIBLE_STRING
Index: 24408
d
= 5F58
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00168 | Error number
Data type: UNSIGNED_32
Index: 24407
d
= 5F57
h
Display of the error number of the first error with highest priority
Display range (min. value | unit | max. value)
0 4294967295
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00169 | Logbook - event filter
Data type: BITFIELD_32
Index: 24406
d
= 5F56
h
Bit-coded word for filtering system events (trouble, warning, information)
A set bit excludes the corresponding event from being entered into the logbook.
From software version V2.0 onwards, bit 0 can be used to activate the option of suppressing successive identical
logbook entries ("multiple entries"). In this case, only the time stamp of the last (most recent) entry is saved
together with the number of occurrences of the event.
Logbook
Value is bit-coded:
Bit 0 No multiple entries
Bit 1 Fault
Bit 2 Trouble
Bit 4 Warning locked
Bit 5 Warning
Bit 6 Information
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00171 | Service code
Data type: UNSIGNED_32
Index: 24404
d
= 5F54
h
This code is used internally by the device and must not be overwritten by the user!