Parameter list | C00357
C00357
C00359
Parameter | Name:
C00357 | CAN RPDOx monitoring time
Data type: UNSIGNED_16
Index: 24218
d
= 5E9A
h
Mapping of RPDO event time (see DS301 V4.02)
• With a value unequal "0", the RPDO will be expected after the set time.
• If the RPDO is not received within this time, a parameterisable error message can be activated.
"CAN on board" system bus
Setting range (min. value | unit | max. value)
0 ms 65535
Subcodes Lenze setting Information
C00357/1 3000 ms Monitoring time for RPDO1 ... RPDO4
C00357/...
C00357/4
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00359 | CAN status
Data type: UNSIGNED_8
Index: 24216
d
= 5E98
h
"CAN on board" system bus
Selection list (display only)
0 Operational
1 Pre-operational
4 Boot up
5 Stopped
7 Reset
8 Initialisation
9 Unknown
10 Baud rate autom. detected