EDS94ARNExxxx EN 2.3 - 06/2014 L 315
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00581
C00581
C00582
C00583
C00584
Parameter | Name:
C00581 | Resp. to external fault
Data type: UNSIGNED_32
Index: 23994
d
= 5DBA
h
Response to an external error
Drive interface
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00582 | Resp. to heatsink temp. > C00122
Data type: UNSIGNED_32
Index: 23993
d
= 5DB9
h
Response if heatsink temperature > variable limit temperature (C00122).
Selection list (Lenze setting printed in bold)
1Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00583 | Resp. to filter KTY overtemp.
Data type: UNSIGNED_32
Index: 23992
d
= 5DB8
h
Response if filter temperature > fixed temperature limit.
Selection list (Lenze setting printed in bold)
1Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00584 | Resp. to filter temp. > C00121
Data type: UNSIGNED_32
Index: 23991
d
= 5DB7
h
Response if filter temperature > variable limit temperature (C00121).
Selection list (Lenze setting printed in bold)
1Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer