9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00613
320 L EDS94ARNExxxx EN 2.3 - 06/2014
C00613
C00614
C00615
Parameter | Name:
C00613 | Resp. to CAN heartbeat error
Data type: UNSIGNED_8
Index: 23962
d
= 5D9A
h
Response if the corresponding heartbeat telegram is not received.
"CAN on board" system bus: heartbeat protocol
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
4 Warning locked
5 Warning
6 Information
0 No response
Subcodes Lenze setting Information
C00613/1 0: No response Response to non-received telegram for monitoring entry
1 ... 32
C00613/...
C00613/32
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00614 | Resp. to CAN life guarding error
Data type: UNSIGNED_8
Index: 23961
d
= 5D99
h
Response of slave if node guarding request is not received.
"CAN on board" system bus: node guarding protocol
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00615 | Resp. to imp. device config.
Data type: UNSIGNED_32
Index: 23960
d
= 5D98
h
Selection list
1Fault
4 Warning locked
6 Information
0 No response
Subcodes Lenze setting Information
C00615/1 0: No response Reserved
C00615/2 1: Fault Resp. to imp. module in MXI1
C00615/3 1: Fault Resp. to imp. module in MXI2
C00615/4 0: No response Reserved
C00615/5 0: No response Reserved
Read access Write access CINH PLC STOP No transfer