EDS94ARNExxxx EN 2.3 - 06/2014 L 321
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00618
C00618
C00625
C00635
C00636
C00637
Parameter | Name:
C00618 | No. of CRC cycles
Data type: UNSIGNED_32
Index: 23957
d
= 5D95
h
Display range (min. value | unit | max. value)
0 4294967295
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00625 | CAN behaviour in case of fault
Data type: UNSIGNED_8
Index: 23950
d
= 5D8E
h
Mapping of the CANopen object I-1029 (see DS301 V4.02)
"CAN on board" system bus
Selection list (Lenze setting printed in bold)
0 State pre-operational
1 No state change
2 State stopped
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00635 | Resp to new firmw. standard dev.
Data type: UNSIGNED_32
Index: 23940
d
= 5D84
h
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning locked
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00636 | Resp. to new module in MXI1
Data type: UNSIGNED_32
Index: 23939
d
= 5D83
h
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning locked
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00637 | Resp. to new module in MXI2
Data type: UNSIGNED_32
Index: 23938
d
= 5D82
h
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning locked
0 No response
Read access Write access CINH PLC STOP No transfer