Doc #: L-2600-1023 Page 8 Rev. 02
Up to 8 programmable limit switch outputs can be added (4 at a time). Both electromechanical
and solid-state outputs are available. Each output is individually configurable on a job-by-job
basis for output logic, related parameters, and a user supplied description.
Separate Top Stop” and “Immediate Stop relay contacts are provided for interface to the press
control.
Up to 4 programmable output relays can be installed that can be configured to indicate various
conditions such as “Crank in Motion”, “Bypassed”, “Down Time Code Active”, “In Setup
Mode”, “Inhibit Condition Active”, and others.
Status messages for each channel indicate the first alarm condition that occurred during the
stroke.
Powerful counting capability with up to two flexibly configured counter sets (each set with part,
bin, and scrap counters that can be driven by stroke or with part sensors).
The system uses an encoder tied to the crankshaft of the press so that position dependent
parameters such as die protection windows, PLS angles, and so on are entered directly in degrees
and require no external cam switches.
The Clutch/Brake signal of the press can be monitored by the 2600 to detect problems with the
coupling of the encoder to the crankshaft such as a broken chain.
The crank angle is always displayed both graphically and in degrees.
Crank speed, distance to bottom, and a number of other readouts are available in the top info
area.
An optional communications card is available with 2 serial ports and an Ethernet port. The
communications card enables the use of the following features:
The optional LinkNet shop floor information collection system networks the unit, collects
downtime, production, and other information, and offers extensive reporting and
management features.
An optional MODBUS protocol (RTU or TCP) can be used over serial port or Ethernet
port for connectivity to PLC’s or data collection programs.
An optional serial feed interface can display and set length, speed, and acceleration for a
wide range of supported servo feeds.
An optional security system interface can allow the use of RFID card readers or
fingerprint readers for user permissions.
1.2 Specifications
Size: 8.75” wide, 6.75” high, 4.5” depth.
Input Power: 90-264 VAC, 47-63 Hz, 17 VA or
24VDC +/- 10% (0.4 Amps).
Press Speed Capability: Up to 2000 strokes per minute