Doc #: L-2600-1023 Page 34 Rev. 02
Navigation Keys
These Up and Down arrow keys are used to select which channel is currently
selected and shown in the detailed information area (and move the channel
cursor as seen by “a” in Figure 24). The first page of this screen shows
channels 1 to 4. When on channel 4, hitting the down arrow again will change
pages to show channels 5 and 6. Likewise, when on channel 5 (the first
channel of the second page), hitting the Up arrow key will change to the first
page and select channel 4.
Display
The blue part of the circular angle display shows the timing window that is set
for the channel, assuming the “Channel Type” requires one. The black arc in
the circular angle display shows the actual angles where the sensor was “On”
in the stroke. This could be displayed as more than one arc if the sensor turns
“On” in multiple places in the stroke. The captured sensor angles are
automatically updated every stroke.
Each channel has a status that indicates any alarms conditions or other
problems related to just that channel.
The overall status of the die protection system.
Softkey
This softkey brings up the channel settings screen for the currently selected
channel (in the example of Figure 24 it would be channel 3). See section 3.3.3
on page 35 for more information on the settings screen.
Press this softkey to go to the die protection bypass screen where various
bypass options can be configured. See section 3.3.6 on page 40 for more
information on the bypass screen.
This softkey Brings up the diagnostics screen for the currently selected
channel (in the example of Figure 24 it would be channel 3). See section 3.3.7
on page 42 for more information on the settings screen.
This softkey is used to reset die protection fault conditions. Note that some
errors, primarily those generated from “Static” inputs, may not clear until
some action is corrected in the die.