[RFID Error ]
[Multi Tag Read ]
or
[RFID Error ]
[Buffer Overflow ]
More than one RFID tag was found in the RF
Field.
- check if there is a paper jam
(compare section 12.3 Incorrect Media
Transport)
- remove the jammed consumables completely
- reload the consumables
(compare section 5.2)
- if you made supply or print position settings,
make sure the RFID tag was set to the right
position
- see section 10.2.3 Adjusting the Transponder
Position, too.
- choose different label material, if the distance
between the tags of your material in use is too
small
If the remedies above are not successful, please call a MICROPLEX
authorized service engineer.