Pellerin Milnor Corporation 17
Electronic Level (Avoid modification) Select whether this machine has electronic level
sensing capability (pressure transducer).
Variable Speed (Avoid modification) Select whether this machine has variable speed
abilities.
Water Levels (Avoid modification) Enter the values for the water levels (in inches or
centimeters) used in bath steps in which the water level is controlled by a pressure transducer.
Water Level 1 must be less than or equal to Level 2. Level 2 must be less than or equal to Level
3.
NOTE: The temperature unit decision determines the water unit. If the temperature unit
is degrees Fahrenheit, the water unit is inches. If the temperature unit is degrees Celsius,
the water unit is centimeters.
Wet-Down (Avoid modification) Enter the wet-down level (in inches or centimeters) for
this machine.
NOTE: The temperature unit decision determines the water unit. If the temperature unit
is degrees Fahrenheit, the water unit is inches. If the temperature unit is degrees Celsius,
the water unit is centimeters.