Dryell (Integrated Door Chute) — Select whether this machine is equipped with a Milnor
®
Integrated Door Chute.
Clockwise Discharge — Enter the duration (in 1/10 seconds) of clockwise rotation while dis-
charging. Valid range is 01 to 99 (0.1 to 9.9 seconds). The cylinder rotates at jog speed, as defined
in Jog Speed (Avoid modification).
Counter-clockwise Discharge — Enter the duration (in 1/10 seconds) of counter-clockwise
rotation while discharging. Valid range is 01 to 99 (0.1 to 9.9 seconds). The cylinder rotates at jog
speed, as defined in Jog Speed (Avoid modification).
Dwell Discharge — Enter the duration (in 1/10 seconds) of dwell (off time) between clockwise
and counter-clockwise rotation when the cylinder turns in both directions while discharging. Val-
id range is 00 to 50 (0 to 5 seconds).
Number of Sequences — Enter the number of times to repeat the discharging sequence of
cylinder rotation and dwell. The valid range is 02 to 20.
End Time — Enter the duration (in minutes) that the machine will run in End mode (see How
to End) in Section 3.1.1.10 : MilTouch-EX™ Wash Formula Decisions, page 33) before it desires
to discharge. Valid range is 0 to 850.
Post-wash — Select whether the controller uses post-wash codes (see Section 3.2 : Post-wash
Codes, page 37).
Dryell Delay — Enter the desired time (in seconds) between when the loading process ends and
the controller commands the washer to tilt to the loading position. Valid range is 000 to 255.
Dryell Flush — Enter the desired time (in seconds) for the controller to flush the Integrated
Door Chute during the loading process. The “Dryell Flush” timer resets to this value each time
the load eye is blocked. Valid range is 000 to 255.
Allied Load — Select whether the controller receives “Start Loading” (3MTA4-13), “Load
Complete” (3MTA4-16), and batch data in binary format from a non-Milnor
®
loading device.
Allied Discharge — Select whether the controller receives a “Start Discharging” command
(3MTA4-17) and sends batch data in binary format to a non-Milnor
®
receiving device.
Early Call — Select whether this machine can prepare to receive new loads while it discharges
loads.
Configuration