99
9−2−2.
Specifications for BCD output
(1)
Output Logic
Related function Changeover of negative logic and Positive logic can be
made with the FUNC−21, FUNC−22, FUNC−23 and
FUNC−25.
(2)
Output data BCD 6 digits parallel output.
POL(Polarity) Output ON at minus
and output OFF at plus.
P.C. (Print Command)
ERROR
D.P. (Decimal Point)
(3)
Input data HOLD Operates between HOLD
and COM is shorted.
BCD−ENABLE Compulsive OFF for the outputs
related with BCD(High impedance).
SEL. 1 Selects the target for output to BCD.
SEL. 2 Selects the target for output to BCD.
SEL. 1
SEL. 2 Output Data
Open Open Display
Short Open A/Z cancellation portion
Open Short Net Weight
Short Short Gross Weight
(4)
Output Target Display, Net Weight and Gross weight with related
function FUNC−20.
External selection(SEL. 1, SEL. 2) can be changed.
(5)
Output Times Synchronous with display times(FUNC−02)
4 times/s, 20 times/s