55
7−6. Various kinds of functions related with display
7−6−1.
Selection of target for display on load display
The load display for the instrument can select from “Net weight” and “Gross weight”. These
selections can be made in Function mode(related Function FUNC−02). As for default, “Net
weight” has chosen.
Warning ● Depending on the selection of target for load display, reading of load
display will differ when Tare(A/Z) function is used. If wrong display
target is selected, there may mistake the load display, or may become
inadequate ON/OFF conditions for comparator, in due course, there
may cause an unexpected accident due to malfunction on peripheral
equipments and so on.
7−6−2.
Lighting up/putting off comparator set value.
The display for comparator setting value on the instrument can charge lighting up or putting
off. This change can be made in Function mode(Related Function FUNC−42). As for default,
“Lights up” is chosen.
When “Puts off” is chosen, comparator set value display will put off, then only judgement
display will light up depending on the situation. At the same time, only when change of set
value for whichever S1, S2, S3 and S4 is made, comparator setting display will light.
● Even when comparator set value puts off, comparative operation for
comparator will be executed.
7−6−3.
Lighting up / Putting off bar meter display
This instrument prepares 11 dots bar meter that can display the ratio of present gross weight in
every 10 % value against maximum display value intervals and change of lighting up / putting
off can be available.
This change can be made in Function mode.(Related Function FUNC−51).
As for default, “Puts off” has chosen.