76
8−2. Function on Function data
・ FUNC−01 Selection of the position of decimal point display.
Initial value = 000000 000000 = Non
000001 = 10
1
000002 = 10
2
000003 = 10
3
000004 = 10
4
・ FUNC−02 Selection of the target for display.
Initial value = 000000 000000 =Net weight(A/Z interlock)
000001 =Net weight(A/Z interlock)
000002 =Gross weight
※ When the “Net weight” is selected, and Tare is executed as well, load display shows
“Net weight”, in the next, when Tare is cancelled, the load display shows “Gross
weight”.
※ When the “Gross weight” is selected, load display shows always fixed “Gross weight”,
whichever Tare is executed or not.
・ FUNC−03 Selection of display times
Initial value = 000000 000000 = 4 times/s
000001 = 20 times/s
・ FUNC−04 Setting digital filter
Initial value = 000003 Setting range := 000000 ~ 000007
mean value of 2
(n+1)
times
※ Selects the average times for digital filter. When the figure grows larger, the filter will
be stronger, then effects from vibration and so on are scarcely shown on the display.
Conversely, if too large one is selected, the response of variation for sensor input will
be worse.
※ Using the digital filter where vibrations may exist is effective for removing the
deflection on display.