6. CNC Data Input/Output
6.16 Various Status
III - 59
Message Error details
Can not write file Could not copy the file to its destination.
Remove the status that does not allow the data to be written. This error
also appears when copying a input protected file from memory card to
CNC.
When a parameter file is input into CNC and this message is displayed,
the error details are also displayed. (Note)
Can not read out file Could not read the file in its source.Remove the status (such as read
protect) that does not allow the data to be read.
Filename illegal The file name is illegal. Try again.
Check the restrictions about directory name and file name on "3.17
Restrictions".
Memory card does not
exist
Card does not exist.
Check whether memory card is inserted.
Check the access switch.
Error Any other error occurred.
Turn off the power supply, check the data in the memory card and
connection status, then try again.
(Note) About error detail
When a parameter file is input into CNC and "Can not write file" error occurs, the error details
are displayed.
A line number of memory card is displayed with "Line", and a parameter number is displayed
with "#".
[Example]
File Name
Error details
[File name]
File name Name
ALL.PRM
SAMPLING.PRM
File for all parameters
Cycle monitor parameter file
PLCSAMP.CTF Cycle monitor data collection setting file (*)
PLCSAMP.MMG Cycle monitor drawing setting file (*)
(*) Parameter number will not be displayed. Only line number is displayed.