7 Before Starting Positioning Operation
56
FX3U-20SSC-H Positioning Block User's Manual 
7.1 Note on Setting Parameters
From the previous page From the previous page
To the next page To the next page
M302
Enables control commands 
in unit No. 1.
Sets to ON the parameter 
initialization command for 
each parameter in unit 
No. 1.
When T1 turns ON, 
initialization of each 
parameter stored in the 
buffer memory in unit No. 1 
is completed. It takes 
20 ms or more for 
initialization.
M303
K5220 U1\G522
FNC 12
MOV
H6300 U1\G523
FNC 12
MOV
M304
Saving the positioning parameters and servo parameters to the flash memory (X-axis and Y-axis)
T1
M305
K5220 U1\G522
FNC 12
MOV
H0063 U1\G523
FNC 12
MOV
Enables control commands 
in unit No. 1.
Sets to ON the command to 
save each parameter to the 
flash memory in unit No. 1.
When T2 turns ON, saving 
(X-axis and Y-axis) to the 
flash memory in unit No. 1 
is completed.  It takes 
4 s or more for saving.  
H0007 U1\G14002
FNC 12
MOV
Sets the operation 
parameter 2 (X-axis) in 
unit No. 1.
T1
Setting the positioning parameters (X-axis)
Setting the positioning parameters (Y-axis)
H0007 U1\G14202
FNC 12
MOV
T1
Sets the operation 
parameter 2 (Y-axis) in 
unit No. 1.
K1 U1\G15000
FNC 12
MOV
Setting the servo parameters (X-axis)
T1
H1 U1\G15003
FNC 12
MOV
K1 U1\G15080
FNC 12
MOV
Sets the servo series 
(X-axis) in unit No. 1.
Sets the absolute position 
detection system (X-axis) 
in unit No. 1.
Sets the function selection 
C-4 (X-axis) in unit No. 1.
K1 U1\G15200
FNC 12
MOV
Setting the servo parameters (Y-axis)
T1
H1 U1\G15203
FNC 12
MOV
K1 U1\G15280
FNC 12
MOV
Sets the servo series 
(Y-axis) in unit No. 1.
Sets the absolute position 
detection system (Y-axis) 
in unit No. 1.
Sets the function selection 
C-4 (Y-axis) in unit No. 1.
SET M304
T1
K1
SET M305
T2
K40
    When each of positioning parameters and servo parameters is at the initial value
    When all positioning parameters and servo parameters will be set. (X-axis and Y-axis)
Initializing the positioning parameters and servo parameters in the buffer memory (X-axis and Y-axis)
Initialization is not required in the following cases.
In these cases, having two MOV instructions in this circuit block is unnecessary. And change the contact 
of T1 to M304.