7 Before Starting Positioning Operation
78
FX3U-20SSC-H Positioning Block User's Manual
7.1 Note on Setting Parameters
From the previous page From the previous page
Saving positioning parameters and servo parameters (X-axis and Y-axis) to the flash memory
K5220 U1\G522
FNC 12
MOV
H007F U1\G523
FNC 12
MOV
SET M353
Enables control
commands in unit No. 1.
Sets to ON the command to
save each parameter and
table information to the flash
memory in unit No. 1.
Indicates that saving to the
flash memory in unit No. 1
is completed.
M351 M352
END
D250 D255
FNC 40
ZRST
M353
T50
K70
When T50 turns ON, saving
of parameters and table
information to the flash
memory in unit No. 1 is
completed.
It takes 7 s or more for
saving.
U1\G519 D254
FNC 12
MOV
Reads the operation
command 2 (X-axis) in
unit No. 1.
Sets (writes) the operation
command 2 (X-axis) in unit
No. 1.
RST D254.B
D254 U1\G519
FNC 12
MOV
T50
Resets the servo parameter
update stop command
(X-axis) in unit No. 1.
U1\G619 D255
FNC 12
MOV
Reads the operation
command 2 (Y-axis) in unit
No. 1.
Sets (writes) the operation
command 2 (Y-axis) in unit
No. 1.
D255 U1\G619
FNC 12
MOV
RST D255.B
Resets the servo parameter
update stop command
(Y-axis) in unit No. 1.
M350 M353
FNC 40
ZRST