3-99 NWA-033623-001 Rev.8.1
91ch3001.fm
COMMAND CODE
TITLE:
LAN DATA ASSIGNMENT
0B
: Default
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING
DATA MEANING DATA MEANING
0XX 0 : Maintenance Port
XX: Unit No. (01-50)
129 IP Address for the trap
source
XXX.XX
...X
NONE
IP Address for the trap
source
(Maximum 15 digits)
XXX.XXX.XXX.XXX=
0.0.0.1-255.255.255.254
No data
NOTE 1: Only Unit No. 01 can be set by this data.
NOTE 2: This data cannot be entered by CAT when using 8300R1 software.
NOTE 3: When setting the IP address by this data, a period (.) must be entered
between the numbers (example: 255.255.255.254).
NOTE 4: The IP address assigned by this data is set to the Agent address in
“SNMP TRAP PDU”, and the system sends the IP address to the IP
network. Wherever the system is located on the LAN, system adminis-
trator can manage it easily by setting of the convenient IP address.
140 IP Address for Stand by
CPU
[8300R4]
XXX.XX
...X
NONE
IP Address
(Maximum 15 digits)
XXX.XXX.XXX.XXX=
0.0.0.1-255.255.255.254
192.168.1.101
NOTE 1: Only Unit No. 01 can be set by this data.
NOTE 2: This data is not effective for Secondary Unit (Unit No. 02-50).
NOTE 3: Reset both Active CPU and Stand by CPU after this data setting.
141 Unit number for
Secondary Unit
[8300R6]
02
50
NONE
Unit No. 02
Unit No. 50
Not set
CM0B
Y=000>90
NOTE 1: Only Unit No. 01 can be set by this data.
NOTE 2: Set this data when Failover mode is used.