: Default
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING
DATA MEANING DATA MEANING
1XX 1 : VOIP Port
XX: Unit No. (01-50)
30
31
32
33
34
35
UDP Port for IP Multi-
line Terminal voice con-
trol
UDP Port for Registra-
tion Admission Status
(RAS) port
UDP Port for DT700
Series voice control
packet
UDP Base Port for SIP
Converter
[8300R3.5]
TCP Server Port for
CCIS
TCP Client Port for
CCIS
01024
65534
NONE
TCP/UDP/RTP Port num-
ber
1st data=30: 50000
(Port number 50000-52047
are used)
1st data=31: 3456
(Port number 3456 is used)
1st data=32: 5080
(Port number 5080 is used)
1st data=33: 5070
(Port number 5070 is used)
1st data=34: 57000
(Port number 57000 is
used)
1st data=35: 58000
(Port number 58000-59023
are used)
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 1: Set this data when the router or firewall provides the restriction by the TCP
port.
NOTE 2: The same port number cannot be used for the port numbers set to the first data
“30-43”.
NOTE 3: When using 8300R6 software or before, only Unit No. 01 can be set by CM0B
Y=1XX>33.
NOTE 4: CM0B Y=1XX>34/35 are not effective for Secondary Unit (Unit No. 02-50).
Continued on next page