: Default
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING
DATA MEANING DATA MEANING
2XX 2 : VOIP Port
XX: Unit No. (01-50)
120 Tone Disabler for the
FAX communication on
the SIP trunk
0
1
Available
Not available
NOTE 1: This data is not effective for Secondary Unit (Unit No. 02-50).
NOTE 2: Tone Disabler is a feature to improve FAX communication rate.
When detecting V.25 tone (2100 Hz) with phase inversion, Echo
Canceller/NLP (Non Linear Processor) is set to OFF. When detecting
V.25 tone (2100 Hz) without phase inversion, Echo Canceller/NLP
(Non Linear Processor) is set as same as voice setting.
121 DTMF inband mode for
Vo I P D B
0
1
In-band mode (Voice pass
through)
Out-band mode (with
H.245 UII/RFC2833)
130 Smooth PAD
[8300R3]
0
1
2
3
4
5
NONE
Disable
-8.2 dBm
-6.4 dBm
-5.3 dBm
-4.2 dBm
-2.1 dBm
As per characteristic level
CM0B
Y=300>XX1
NOTE 1: Do not change this data when the system is operated normally.
NOTE 2: The meaning of this command depends on the level of characteristics
when the second data is default data.
- Characteristic level is No. 00: COT/LD/OD(2W) ............ -4.2 dBm
- Characteristic level is not No. 00: Station/
Trunk except COT/LD/OD(2W) ........................................ -2.1 dBm
NOTE 3: This data is ineffective when PZ-64IPLC-A/PZ-128IPLC-A is used.
140 CNG attenuation level
[8300R3]
0
1
2
3
+3 dB
-6 dB
-3 dB
0 dB
NOTE 1: Do not change this data when the system is operated normally.
NOTE 2: This data is ineffective when PZ-64IPLC-A/PZ-128IPLC-A is used.
Continued on next page