: Default
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
96 Standard SIP station con-
nection status
[8300R3.5]
0
1
NONE
Not connected (Display only)
Connecting (Display only)
Other than Standard SIP station (Display only)
CCC Idle Return (Forced)
NOTE 1: When a station during calling is set forced idle return by this data, the forced idle return is completed
and the call is terminated.
NOTE 2: Re-register the Standard SIP station by CMBC Y=15 after forced idle return by this data.
NOTE 3: When an unassigned number is set to the first data of this data, “DATA NOT FOUND” is displayed.
NOTE 4: When assigning forced idle return for a disconnected station displayed “0” as readout data of this data,
“DATA ERROR” is displayed and the forced idle return is not executed.
97 IP address of Standard SIP
station without REGISTER
[8300R5]
X.....XXX
(maximum
12 digits)
NONE
IP address of Standard SIP station without REGIS-
TER
XXXXXXXXXXXX=
000000000001-255255255254
No data/Other than Standard SIP station
CMBC Y=15
NOTE 1: Set this data to the related station before registering Standard SIP station without REGISTER by CMBC
Y=15.
NOTE 2: When the IP address is changed or deleted by specifying the registered Standard SIP station, “WAIT,
BUSY NOW” is displayed (the IP address is not changed or deleted).
NOTE 3: When changing the IP address assigned by this data, delete the registered terminal once by CMBC
Y=15. Then register the terminal again.
98 Port number of Standard
SIP station without REGIS-
TER
[8300R5]
00000
65534
NONE
Port number of Standard SIP station without REG-
ISTER
5060/Other than Standard SIP station
CMBC Y=15
NOTE 1: When using the port number other than 5060 (default), set this data to the related station before regis-
tering Standard SIP station without REGISTER by CMBC Y=15.
NOTE 2: When the IP address is changed or deleted by specifying the registered Standard SIP station, “WAIT,
BUSY NOW” is displayed (the IP address is not changed or deleted).
NOTE 3: When changing the port number assigned by this data, delete the registered terminal once by CMBC
Y=15. Then register the terminal again.