3-182 NWA-033623-001 Rev.8.1
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-2
13
: Default
Y SETTING DATA
No. MEANING DATA MEANING
33 Port mode of Analog Port Adapter/
PGD(2)-U10 ADP
See PRECAUTION (4)
0
1
Dual port mode
Single port mode
34 Designation of station connected to Dual
port mode of Analog Port Adapter/
PGD(2)-U10 ADP
See PRECAUTION (4)
0
1
Station connected to Dual port mode of Analog Port
Adapter/PGD(2)-U10 ADP
Station not connected to Analog Port Adapter/
PGD(2)-U10 ADP
35 Send or not ringing signal to the single
line telephone connected to Analog Port
Adapter
0
1
Not sent
To send
37 VMS Soft Key feature
NOTE: Set this data to VMS station
number.
0
1
To provide
Not provided
39 WCS Roaming for Virtual Station of Vis-
itor PS
[For PCS] [8300R2]
0
1
Available
Not available
40 Station number assigned by CM11 for
BLF-CCIS
0
1
Other office station
Own office station
41 Storage of the call history (IC) when
answering a station call
0
1
To store
Not stored
45 Group Call by Pilot Number Dialing 0
1
To provide
Not provided
46 Call Forwarding-No Answer Timing 0
1
As per CM41 Y=0>100, 101/CME6 Y=07, 08
As per CM41 Y=0>01, 15
NOTE: Call Forwarding-No Answer Timing is as follows when second data is set as 0.
When the timer for each station is set up by CME6 Y=07, 08: The timer of CME6 Y=07, 08 is effective.
When the timer for each station is not set up by CME6 Y=07, 08: The timer of CM41 Y=0>100, 101
is effective.
49 Storage of the call history (IC) when han-
dling of unanswered call
0
1
To store
Not stored
Continued on next page