: Default
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 37 Tone Duration (Off time) of MFC (Forward
Signal/Backward Signal)
[8300R3.5]
00
09
NONE
1 dB
Increment unit: 1 dB
10 dB
10 dB
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
38 Forward signal receiver S/N ratio
[8300R3.5]
00
01
02
03
04
NONE
0 dB
-5 dB
-10 dB
-15 dB
-20 dB
-10 dB
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
39 Forward signal receiver ON detect time
[8300R3.5]
01
98
99
NONE
30 ms.
Increment unit: 15 ms.
1485 ms.
3840 ms.
30 ms.
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
40 Forward signal receiver OFF detect time
[8300R3.5]
01
98
99
NONE
30 ms.
Increment unit: 15 ms.
1485 ms.
3840 ms.
30 ms.
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
41 Backward signal receiver Start delay time
[8300R3.5]
00
98
99
NONE
0 ms.
Increment unit: 0.25 ms.
24.5 ms.
64 ms.
0 ms.
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
Continued on next page