: Default
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 42 Backward signal receiver Detect Level
[8300R3.5]
00
01
02
03
04
05
06
NONE
Detect Level 0: 0 to -25 dBm
Detect Level 1: -5 to -30 dBm
Detect Level 2: -10 to -35 dBm
Detect Level 3: -15 to -40 dBm
Detect Level 4: -20 to -45 dBm
Detect Level 5: -25 to -50 dBm
Detect Level 6: -30 to -55 dBm
Detect Level 0: 0 to -25 dBm
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
43 Backward signal receiver Minimum Detect
Level
(for Detect Level 0/1/2/3/4/5/6)
[8300R3.5]
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
NONE
-10/-15/-20/-25/-30/-35/-40 dBm
-11/-16/-21/-26/-31/-36/-41 dBm
-12/-17/-22/-27/-32/-37/-42 dBm
-13/-18/-23/-28/-33/-38/-43 dBm
-14/-19/-24/-29/-34/-39/-44 dBm
-15/-20/-25/-30/-35/-40/-45 dBm
-16/-21/-26/-31/-36/-41/-46 dBm
-17/-22/-27/-32/-37/-42/-47 dBm
-18/-23/-28/-33/-38/-43/-48 dBm
-19/-24/-29/-34/-39/-44/-49 dBm
-20/-25/-30/-35/-40/-45/-50 dBm
-21/-26/-31/-36/-41/-46/-51 dBm
-22/-27/-32/-37/-42/-47/-52 dBm
-23/-28/-33/-38/-43/-48/-53 dBm
-24/-29/-34/-39/-44/-49/-54 dBm
-25/-30/-35/-40/-45/-50/-55 dBm
-25/-30/-35/-40/-45/-50/-55 dBm
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.