EasyManua.ls Logo

NEC Univerge SV8300 - Page 335

NEC Univerge SV8300
804 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-279 NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Default
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 44 Backward signal receiver Maximum Detect
Level
(for Detect Level 0/1/2/3/4/5/6)
[8300R3.5]
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
NONE
0/-5/-10/-15/-20/-25/-30 dBm
-1/-6/-11/-16/-21/-26/-31 dBm
-2/-7/-12/-17/-22/-27/-32 dBm
-3/-8/-13/-18/-23/-28/-33 dBm
-4/-9/-14/-19/-24/-29/-34 dBm
-5/-10/-15/-20/-25/-30/-35 dBm
-6/-11/-16/-21/-26/-31/-36 dBm
-7/-12/-17/-22/-27/-32/-37 dBm
-8/-13/-18/-23/-28/-33/-38 dBm
-9/-14/-19/-24/-29/-34/-39 dBm
-10/-15/-20/-25/-30/-35/-40 dBm
-11/-16/-21/-26/-31/-36/-41 dBm
-12/-17/-22/-27/-32/-37/-42 dBm
-13/-18/-23/-28/-33/-38/-43 dBm
-14/-19/-24/-29/-34/-39/-44 dBm
-15/-20/-25/-30/-35/-40/-45 dBm
0/-5/-10/-15/-20/-25/-30 dBm
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
45 Backward signal receiver twist Level
[8300R3.5]
00
09
NONE
1 dB
Increment unit: 1 dB
10 dB
10 dB
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
46 Backward signal receiver S/N ratio
[8300R3.5]
00
01
02
03
04
NONE
0 dB
-5 dB
-10 dB
-15 dB
-20 dB
-10 dB
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
Continued on next page
~
~
JANUARY/14/2011
CM31

Table of Contents

Other manuals for NEC Univerge SV8300