3-280 NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Default
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 47 Backward signal receiver ON detect time
[8300R3.5]
01
98
99
NONE
30 ms.
Increment unit: 15 ms.
1485 ms.
3840 ms.
30 ms.
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
48 Backward signal receiver OFF detect time
[8300R3.5]
01
98
99
NONE
30 ms.
Increment unit: 15 ms.
1485 ms.
3840 ms.
30 ms.
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
49 Number of received digits of called number
from PSTN
[8300R3.5]
01
31
NONE
1 digit
Increment unit: 1 digit
31 digits
31 digits
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
50 Number of received digits of ANI signal
from PSTN
[8300R3.5]
01
31
NONE
1 digit
Increment unit: 1 digit
31 digits
16 digits
51 Forward signal meaning no ANI signal on
DOD/DID MFC call
[8300R3.5]
01
15
NONE
Forward GI-1
Forward GI-15
No data
90 MFC Signaling Data Soft Reset
[8300R3.5]
0
1
To reset
Already reset
NOTE: Reset MFC Signaling Data after confirming all the MFC-trunk are not used.