3-281 NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Default
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
B 00 Duration from sending start Forward
signal to receiving Backward signal
[Not used in North America]
01
31
NONE
1 second
Increment unit: 1 second
31 seconds
12 seconds
01 Duration from detecting Backward
signal to receiving stop Backward signal
[Not used in North America]
01
31
NONE
1 second
Increment unit: 1 second
31 seconds
12 seconds
06 Duration from sending start Backward
signal to receiving stop Forward signal
[Not used in Australia/
North America]
01
31
NONE
1 second
Increment unit: 1 second
31 seconds
24 seconds
07 Duration from detecting receiving stop
Forward signal to receiving next Forward
signal
[Not used in Australia/
North America]
01
31
NONE
1 second
Increment unit: 1 second
31 seconds
24 seconds
11 Sending duration of Backward signal
[Not used in Australia/
North America]
00
01
12
NONE
0 ms.
50 ms.
Increment unit: 50 ms.
600 ms.
NOTE
NOTE: When this data is not assigned, system continue to send Backward signal until receiving For-
ward signal.
Continued on next page
RESET
~
~
RESET
~
~
RESET
~
~
RESET
~
~
RESET
~
~
APRIL/16/2010
CM31