3-294 NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE
TITLE:
TRUNK ROUTE DATA
35
: Default
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
024 DTMF Inter-digital pause 0
1
2
3
4
5
6
7
32 ms.
64 ms.
80 ms.
96 ms.
160 ms.
192 ms.
240 ms.
128 ms.
025 DP Make Ratio
See PRECAUTION (2)
0
1
39 % Make Ratio
33 % Make Ratio
NOTE: This command is available for LDT/ODT when using 8300R6 software or later.
026 DTMF signal width 0
1
64 ms.
128 ms.
028 Outgoing Trunk Queuing 0
1
Not allowed
Allow
CM15 Y=002
032 Distinctive lamp indication
on Multiline Terminal dur-
ing external incoming call
termination
0
1
Green (120 IPM)
Red (120 IPM)
CM08>137
NOTE: The lamp indication for an internal incoming call is red (120 IPM flashing). For indicating the termi-
nation of transferred external incoming call, the flashing lamp color depends on CM08>137.