3-295 NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE
TITLE:
TRUNK ROUTE DATA
35
: Default
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
033 Interval of Multiline Termi-
nal ringing signal to station
on incoming calls
[Other than North
America]
0
1
2
3
Ringing NOTE
Special Ringing
Internal Ringing
External Ringing
CM08>397
NOTE: For Multiline Terminal, Special Ringing; 0.5 seconds ON-0.5 seconds OFF [For Australia/Asia/
Africa/Europe/Latin America/Middle East/Russia] or 0.25 seconds ON-0.25 seconds OFF-0.25
seconds ON-0.25 seconds OFF [For EU] is applied.
Interval of Multiline Termi-
nal ringing signal to station
on incoming calls
[North America Only]
0
1
2
3
0.4 seconds ON-0.2 seconds OFF-0.4 seconds
ON-2 seconds OFF
0.4 seconds ON-0.2 seconds OFF-0.4 seconds
ON-2 seconds OFF
1 second ON-2 seconds OFF
2 seconds ON-4 seconds OFF
NOTE: For incoming calls to Trunk Line Appearance key on Multiline Terminal, the special ringing; 0.2 sec-
onds ON-0.2 seconds OFF will be applied.
Interval of Single Line
Telephone ringing signal to
station on incoming calls
0
1
2
3
As per CM04 Y=00>05
As per CM04 Y=00>07
As per CM04 Y=00>05
As per CM04 Y=00>06
CM04 Y=00>05,
06, 07
Continued on next page
See CM08>397