: Default
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
189 Trunk access code for
Trunk-Direct Appearances
Multiline Operation
X
XX
NONE
Trunk Access Code to be added
X: 0-9, A (*), B (#)
No data
CM35 Y=044
192 Tandem calls to CCT/IPT
(P2P CCIS) with Alternate
Routing for a fault occur-
rence
0
1
To provide
Not provided
CM35 Y=186
193 Characteristic level
[8300R3]
06
09
NONE
Characteristic level
No data
CM0B Y=300-350
NOTE: Do not change this data when the system is operated normally.
196 Q-SIG Facility 00
15
Q-SIG
No data
CM35 Y=90: 0
NOTE: This command is effective when CM35 Y=90: 0 (No. 7 CCIS).
197 Object ID assignment of
Q-SIG Facility Information
Element
0
1
Global
Local
Continued on next page