Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
0 03 Timing for Pseudo-
Answer signal sent to
SMDR
NONE 00 01 02 03 04 05 06 07 08
4 seconds
20
24
seconds
4 8 12 16 20 24 28 32 36
8 1216202428323640
04 Guard Timing of trunk
release
NONE 01 02 03 04 05 06 .......................13 14
0.48 seconds
1.92
2.40
seconds
0 0.48 0.96 1.44 1.92 2.40 .................... 5.76 6.24
0.48 0.96 1.44 1.92 2.40 2.88.................... 6.24 6.72
05 Recall Timing for
Non-exclusive Hold/
Call Park
NONE 01 02 03 ...............................................98 99
4 seconds
60
64
seconds
0 4 8 ...............................................388
4 8 12 ..............................................392
NOTE: When timer data 99 is assigned, the call is not
recalled.
06 Recall Timing for
Exclusive Hold/
Remote Hold
NONE 01 02 03 04 05 06 .......................98 99
4 seconds
236
240
seconds
0 4 8 12 16 20 ......................388
4 8 12 16 20 24 ......................392
NOTE: When timer data 99 is assigned, the call is not
recalled.
07 Recall Timing after
station release for call
transfer
NONE 01 02 03 04 05 06 .......................29 30
4 seconds
24
28
seconds
0 4 8 12 16 20 ...................... 112 116
4 8 12 16 20 24 ......................116 120
09 Periodic Time Indica-
tion Tone
NONE 01 02 03 04 05 06 .......................16 17
32 seconds
192
196
seconds
32 64 96 128 160 192 .....................512 544
36 68 100 132 164 196 .....................516 548
Continued on next page