3-336 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
0 11 Attendant Recall of
held call
[8300R2]
NONE 01 02 03 04 05 06 .......................13 14
2.4 seconds
31.2
33.6
seconds
0 2.4 4.8 7.2 9.6 12.0 .................... 28.8 31.2
2.4 4.8 7.2 9.6 12.0 14.4.................... 31.2 33.6
15 16 17 18 19 .........................................24
9.6 seconds
28.8 38.4 48.0 57.6 67.2..................................... 115.2
38.4 48.0 57.6 67.2 76.8..................................... 124.8
13 Single digit dialing
time-out (Timing
Start)
NONE 03 04 05 06 07 08
1 second
4
5
seconds
234567
345678
14 DTMF signal width of
Out Pulse-Long from
Attendant Console
[8300R2]
NONE 01 02 03 04 05 06 .................................50
64 ms.
512 ms. 64 128 192 256 320 384 ..............................3200
15 Elapsed time before
Call Forwarding-No
Answer for internal
call and assisted call
NONE 01 02 03 04 05 06 .......................29 30
4 seconds
32
36
seconds
0 4 8 12 16 20 ...................... 112 116
4 8 12 16 20 24 ......................116 120
NOTE: For the timer of the second call forwarding,
see CM41 Y=0>46.