3-340 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
0 45 Announcement Ser-
vice Timer
NONE 01 02 .................................................................99
4 seconds
60
64
seconds
0 4 .................................................................392
4 8 .................................................................396
46 Timing of Multiple
Call Forwarding No
Answer after second
forwarding
NONE 01 02 03 ...............................................29 30
4 seconds
32
36
seconds
0 4 8 ............................................... 112 116
4 8 12 ..............................................116 120
47 Interval Time of ACD/
UCD Delay
Announcement/Atten-
dant Delay Announce-
ment
NONE 01 02 .................................................................30
4 seconds
32
36
seconds
0 4 .................................................................116
4 8 .................................................................120
48 DTMF Signal Width
for VMS
NONE 00 01
64 ms.
128 ms. 64 128
49 DTMF Interdigit
Pause for VMS
NONE 00 01 02 03 04 05 06 07 32 ms.
(00-01)
16 ms.
(01-02)
20 ms.
(02-04)
40 ms.
(04-07)
160 ms. 32 64 80 100 120 160 200 240
50 Timing Start when
making ISDN call
from station
NONE 03 04 05 .........................................................14
1 second
10
seconds
3 4 5 ..........................................................14
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
APRIL/16/2010
CM41

Table of Contents