EasyManua.ls Logo

NEC Univerge SV8300 - Page 397

NEC Univerge SV8300
804 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-341 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
0 51 Message Replay Timer
for Automated Atten-
dant
NONE 01 02 03 .........................................................31
4 seconds
64
68
seconds
4 8 12 ........................................................124
8 12 16 ........................................................128
NOTE: In case that the recording time of Voice Re-
sponse System is shorter than the time assigned
by command (CM41Y=0>51), Voice Response
System will be released when the message re-
ply is finished (The message reply will not be
repeated).
52 Message Replay Timer
for Automatic Wake
Up/Timed Reminder
NONE 01 02 03 .........................................................99
4 seconds
60
64
seconds
0 4 8 .........................................................392
4 8 12 ........................................................396
53 Message Replay Timer
for Announcement Ser-
vice
NONE 01 02 03 .........................................................99
4 seconds
60
64
seconds
0 4 8 .........................................................392
4 8 12 ........................................................396
54 Forced release timing
for tandem connection
NONE 01 02 03 .........................................................06
32 minutes
96
128
minutes
32 64 96 ........................................................192
64 96 128 .......................................................224
NOTE: With this timing, the tandem connection is re-
leased, unless the incoming trunk does not re-
ceive the release signal.
55 Forced release timing
for unanswered call
with tandem connec-
tion or trunk to trunk
connection when a sta-
tion holds another sta-
tion/trunk
NONE 01 02 03 04 .................................................13
4 seconds
20
24
seconds
8 12 16 20 .................................................56
12 16 20 24 .................................................60
NOTE: This data is available when the incoming trunk
cannot receive a release signal.
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
APRIL/16/2010
CM41

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals