Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
0 133 Expire value for
DT700 Series SUB-
SCRIBE for Server
(Day)
NONE 00 01 02 .........................................................99
1 day
1 hour 0 1 2 ..........................................................99
NOTE 1: Usually, this data setting is not required.
NOTE 2: This data implies the expire value for the DT700 Series
SUBSCRIBE (terminal control signal from DT700 Series
to SV8300) and is set by the combination of CM41
Y=0>133-135 (day/hour/minute).
When CM41 Y=0>133-135 (day/hour/minute) are all set
to NONE, the expire value “3600 seconds” is set as de-
fault.
NOTE 3: The DT700 Series updates the SUBSCRIBE at half inter-
val of the value set by this data.
NOTE 4: The load to SV8300 increases if small amount of data
(such as 1 minute) is set. Therefore, it is recommended to
set the value more than 1 hour (3600 seconds).
NOTE 5: After setting this data, a reset of the terminal is required.
134 Expire value for
DT700 Series SUB-
SCRIBE for Server
(Hour)
NONE 00 01 02 .........................................................23
1 hour
1 hour 0 1 2 ..........................................................23
NOTE: See NOTE 1 through NOTE 5 on CM41
Y=0>133.
135 Expire value for
DT700 Series SUB-
SCRIBE for Client
(Minute)
NONE 00 01 02 .........................................................59
1 minute
1 hour 0 1 2 ..........................................................59
NOTE: See NOTE 1 through NOTE 5 on CM41
Y=0>133.
Continued on next page