Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
0 123 Timing of Caller ID
station until sending
Caller ID signal after
the first ringer begins
to send
NONE 00 01 02 .........................................................25
100 ms.
1500 ms.
(CM08>
592: 0)/
2500 ms.
(CM08>
592: 1)
0 100 200 ......................................................2500
130 Expire value for
DT700 Series REGIS-
TER (Day)
NONE 00 01 02 .........................................................99
1 day
3 minutes 0 1 2 ..........................................................99
NOTE 1: Usually, this data setting is not required.
NOTE 2: This data implies the expire value for the DT700 Series
REGISTER (terminal registration) and is set by the
combination of CM41 Y=0>130-132 (day/hour/minute).
When CM41 Y=0>130-132 (day/hour/minute) are all set
to NONE, the expire value “180 seconds” is set as de-
fault.
NOTE 3: The DT700 Series updates the REGISTER at half interval
of the value set by this data.
NOTE 4: The load to SV8300 increases if small amount of data
(such as 1 minute) is set. Therefore, it is recommended to
set the value more than 180 seconds.
NOTE 5: After setting this data, a reset of the terminal is required.
131 Expire value for
DT700 Series REGIS-
TER (Hour)
NONE 00 01 02 .........................................................23
1 hour
3 minutes 0 1 2 ..........................................................23
NOTE: See NOTE 1 through NOTE 5 on CM41
Y=0>130.
132 Expire value for
DT700 Series REGIS-
TER (Minute)
NONE 00 01 02 .........................................................59
1 minute
3 minutes 0 1 2 ..........................................................59
NOTE: See NOTE 1 through NOTE 5 on CM41
Y=0>130.
Continued on next page