Chapter 1 HOW TO USE CAT
1-29 NWA-033623-001 Rev.8.1
91ch1001.fm
ERROR MESSAGES
Error Messages
ERROR MESSAGE MEANING OF MESSAGE ACTION
SD CODE NOT
ALLOWED/CODE
NOT ALLOWED
NOTE
Second data which is not allowed in
the current status.
Check whether the second data is
available or not.
CM CODE NOT USED/
CODE NOT USED
NOTE
The command code entered is not in
use, or password is needed.
Depress “ST” or “CE” and enter the
correct data.
FD CODE NOT USED/
CODE NOT USED
NOTE
The first data entered is not in use, or
password is needed.
SD CODE NOT USED/
CODE NOT USED
NOTE
The second data entered is not in use,
or password is needed.
Depress “ST” or “CE” and enter the
correct data.
DATA NOT FOUND A station number not assigned has
been entered.
WAIT, BUSY NOW The station or trunk, for which data
is to be changed, is busy.
Wait until it becomes idle.
ASSIGNED ALREADY This error message is displayed when
not enough digits are entered. For
example, when assigning “12” for a
service access code, even if “123”
has been already used for another
service access code.
Depress “ST” or “CE” and enter the
correct data.
HARDWARE ERROR Memory read/write disabled. Check the switch setting of CPU
blade or replace the CPU blade with
spare.