Chapter 2 PRECAUTION
2-5 NWA-033623-001 Rev.8.1
91ch2001.fm
CONDITIONS FOR USING COMMANDS
Conditions for Using Commands
NOTE: Before the CPU blade is placed into Off-Line mode, the system data backup must be executed
by CMEC Y=6>0: 0.
CONDITION COMMANDS MEANINGS
Commands which can be
used only under Off-Line
mode of the CPU blade. See
“METHOD OF SETTING
ON-LINE/OFF-LINE
MODE”. Page 2-6
NOTE
CM00 System Data Memory All Clear/SRAM Clear
CM01 System Data Memory Partial Clear
CM0B Y=000 LAN Data Assignment
CM4A Y=90 Day/Night Mode Change by System Clock,
Automatic RC/DND Mode Select by System
Clock
CMEC Y=7 Maintenance by PCPro/CAT
Commands which require a
reset of the IPT (P2P CCIS)
after data setting.
Executed by CME0
Y=5>01
CM0B Y=1XX>34, 35 LAN Data Assignment
CM10 Y=02 Station Number, Trunk Number, Blade Num-
ber
CM30 Y=00 Trunk Data
CMA7 Y=44, 46, 50 CCIS Channel/IP Trunk/SIP Trunk Data 1
OFF LINE
IPT (P2P CCIS) RESET
JUNE/15/2011