: Default
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
03 Echo Canceller
between locations
XX ZZ XX: Location
number
(00-63)
ZZ : Location
number
(00-63)
00
01
NONE
CCC
Echo Canceller OFF
Echo Canceller ON
Echo Canceller ON
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
NOTE: This data setting is valid to the location that is set to “XX” in the first data.
04 Minimum value of
jitter buffer
between locations
XX ZZ XX: Location
number
(00-63)
ZZ : Location
number
(00-63)
01
30
NONE
CCC
10 ms.
300 ms.
(10 ms. increments)
10 ms.
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CMAD Y=29
NOTE 1: When setting this data to other than default, set CM67 YY=05 to other than default.
NOTE 2: Assign the value which does not exceed the maximum value of jitter buffer set by CM67 Y=05.
NOTE 3: When this data is set to other than NONE, assign CM67 Y=05 to other than NONE to be effective for
this data.
NOTE 4: Jitter buffer of PZ-64IPLC-A/PZ-128IPLC-A (VoIPDB) is controlled as 200 ms., when minimum val-
ue of jitter buffer is set more than 210 ms.
NOTE 5: This data setting is valid to the location that is set to “XX” in the first data.
05 Maximum value of
jitter buffer
between locations
XX ZZ XX: Location
number
(00-63)
ZZ : Location
number
(00-63)
01
30
NONE
CCC
10 ms.
300 ms.
(10 ms. increments)
300 ms.
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CMAD Y=29
NOTE 1: When setting this data to other than default, set CM67 YY=04 to other than default.
NOTE 2: Assign the value which exceeds the minimum value of jitter buffer set by CM67 Y=04.
NOTE 3: When this data is set to other than NONE, assign CM67 Y=04 to other than NONE to be effective for
this data.
NOTE 4: This data setting is valid to the location that is set to “XX” in the first data.
Continued on next page