: Default
YSETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
00 Setting of Functions F7XXZ Relay Control Function Key
XX : Relay Group No. (00-31)
assigned by CM44
Z : Circuit No. (0-3) assigned by
CM44
312, 313: External Relay Interface of CPU
blade
CM44 Y=00:
1500
01 Multiline Terminal ring-
ing tone by Day Mode/
Night Mode
0
1
2
3
Day Mode: No ringing/Night Mode:
Ringing
Day Mode: Ringing/Night Mode:
No ringing
Day Mode: No ringing/Night Mode:
No ringing
Day Mode: Ringing/Night Mode: Ringing
CM08>577
02 Ringing sending
method when terminat-
ing a call to Line/Trunk
key on Multiline Termi-
nal
0
1
Delayed Ringing
No Delayed Ringing
NOTE: Delayed Ringing can be assigned
to the first 16/24 Line/Trunk keys.
CM41 Y=1>09
CM12 Y=24
03 Call Indicator Lamp
control
0
1
Not available
Available (The lamp lights on call termina-
tion or recall.)
04 Group Feature Key 0
1
To provide
Not provided
NOTE: Do not set the second data 0 to the
My Line number of Multiline Ter-
minals.
CM08>199, 588
09 Copy of Multiline Ter-
minal key assignment
[8300R3]
X
XXXXXXXX
NONE
Copied Station number (Digital Multiline
Terminal and IP Multiline Terminal Only)
No data
NOTE 1: When the copied station is busy, “WAIT, BUSY NOW” is displayed on LCD.
NOTE 2: Add-on module key assignment cannot be copied.
Continued on next page