: Default
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
103 Setting of Authentica-
tion password when
registering to/sending
from the SIP server
with character code
(Last 12 characters)
00
31
Profile number
for control packet
XXX...X
NONE
Password
(16 digits, 8 charac-
ters fixed)
See Character
Code Table in
CM77.
No data
CMA7 Y=71
CMBA Y=74,
75, 102
NOTE 1: When the character code to be set is less than the number of digits necessary, add the character
code FF.
NOTE 2: You can confirm the password set by this command with CMBA Y=74.
NOTE 3: Set the second data to NONE for Point-to-Multipoint connection (when CMA7 Y=46 is set to “0”).
104 Periodical resending of
provisional response
when receiving to SIP
trunk
[North America
Only]
[8300R4]
00
31
Profile number
for control packet
0
1
3
To provide
To provide only when
100rel is provided
Not provided
CMA7 Y=71
NOTE 1: 0 (To provide) or 1 (To provide only when 100rel is provided) should be set when long duration
ringing (3 minutes and more) is provided for incoming calls to SIP trunk from SIP server.
NOTE 2: When the SIP trunk in communicated system does not support 100rel, if 0 (To provide) is set by
this command, the SIP trunk may remain called when some failure occurs on the SIP trunk in the
communicated system.
105 Request provisional
responses with reliabil-
ity (100rel) when send-
ing from SIP trunk
00
31
Profile number
for control packet
0
1
3
Available (Supported
header and Require
header)
Available (Supported
header)
Not available
CMA7 Y=71
Continued on next page