3-687 NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE
TITLE:
MAINTENANCE BY PCPro/CAT
EC
System Data Backup
NOTE 6: You can assign only “0” to the second data. “1” is displayed while the system data is being
copied.
NOTE 7: Backup takes about 5 minutes on On-line/Off-line mode. While saving the system data to flash
memory, “SYSD” LED on the CPU blade flashes.
NOTE 8: Do not turn off or reset the system while “SYSD” LED on the CPU blade is flashing.
SDRAM Data Clear
NOTE 9: Execute the system data backup by CMEC Y=6>0: 0 after this data clear.
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
6 System data
backup
0 System data backup 0
1
3
Start to save
Now saving
Stand by
NOTE 6
CM43 Y=5
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
7 SDRAM Data
Clear
00 ID registration for
IP Station in Auto-
matic Login Mode
all clear
CCC Clear NOTE 9
APRIL/16/2010
CMEC