143 Preface 143
Name
Number of
Parameters
Function
Legacy
Commands
PM:MAX:Lambda?
NONE
Returns the longest calibrated wavelength in
nanometers.
PM:MAX:Power?
NONE
Returns current range’s maximum readable power.
PM:MIN:Lambda?
NONE
Returns the shortest calibrated wavelength in
nanometers.
PM:MODE
1
MODE_n
PM:MODE?
NONE
Returns the currently selected acquisition mode.
MODE_n?
PM:Power?
NONE
Returns the power in the selected units.
R_n?
PM:PWS?
NONE
Returns the power with status.
RWS_n?
PM:RANge
1
Selects the gain stage when making readings with the
detector head within a range from 0 to 5 (with zero
being the highest).
RANGE_n
PM:RANge?
NONE
Returns an integer indicating the current range.
RANGE_n?
PM:RESPonsivity?
NONE
Gets the responsivity currently used for making power
calculations.
RESP_n?
PM:RUN
1
Disables or enables the acquisition of data.
RUN_n,
STOP_n
PM:RUN?
NONE
Returns the present acquisition mode.
RUN_n?,
STOP_n
PM:STAT:MAX?
NONE
Return statistics buffer maximum value.
STMAX_n?
PM:STAT:MEAN?
NONE
Return statistics buffer mean value.
STMEAN_n?
PM:STAT:MIN?
NONE
Return statistics buffer minimum value.
STMIN_n?
PM:STAT:MAXMIN?
NONE
Return statistics buffer maximum-minimum value.
STMXMN_n?
PM:STAT:SDEViation?
NONE
Return statistics buffer standard deviation value.
STSDEV_n?
PM:Temp?
NONE
Returns the 918 detector's temperature in degrees
Celsius.
PM:THERM:PREDICT
1
Disables or enables thermopile prediction algorithm
PM:THERM:PREDIC ?
NONE
Returns the present thermopile prediction algorithm
state
PM:TRIG:EXTernal
1
Set external trigger enable.
EXT
PM:TRIG:EXTernal?
NONE
Return external trigger enable.
EXT?
PM:TRIG:EDGE
1
Set external trigger edge select.
EXTEDGE
PM:TRIG:EDGE?
NONE
Return external trigger edge select.
EXTEDGE
PM:TRIG:HOLDoff
1
Set external trigger holdoff time.
EXTHOLDOFF
PM:TRIG:HOLDoff?
NONE
Return external trigger holdoff time.
EXTHOLDOFF?
PM:UNITs
1
Selects the units for readings.
UNITS_n
PM:UNITs?
NONE
Returns an integer indicating the selected units.
UNITS_n?
PM:REF:VALue
1
Sets the user reference value for use in relative or dB
readings.
USRREF_n
PM:REF:VALue?
NONE
Returns the user reference value.
USRREF_n?
PM:REF:STOre
NONE
Sets the user reference value for use in relative or dB
readings as the present reading.
STOREF_n
PM:ZEROSTOre
NONE
Sets the zeroing value with the present reading.
STOZERO_n
PM:ZEROVALue
1
Sets the zeroing value.
ZEROVAL_n
PM:ZEROVALue?
NONE
Gets the zeroing value.
ZEROVAL_n?