39
NOTE: To use this function, we suggest the purchase of a TERMINAL BLOCK
MODULE.
The internal relay contained in the TERMINAL BLOCK MODULE is intended for
integration with monitored alarm panels. EXAMPLE:
*Event report generated through a PC with the Guarita IP Software.
The “Backup” function is used to copy the information stored in the “Internal Me-
mory” of the MG3000 to a ash drive. After making the copy, the ash drive
will have stored all the MG3000’s programming, including congurations, event
reports and registered devices. This data will be stored in the ash drive and
identied by date, time and the label congured in the option “SUPPORT”.
To perform the backup, with the ash drive connected to the MG3000, in the
basic menu, select the option “BACKUP”, then press “Conrm?”. Wait until the
device, event, conguration and biometrics records are copied. This process may
take a few minutes depending on the amount of information stored.
If the space on the ash drive is insucient for storage of the backup, a failure
message will be displayed. In this case, remove the ash drive, free up space
on the device or replace it with another one with available space and redo the
backup procedure. A full backup of registered events and devices will be done
automatically every 8192 events occurred on the internal SD Card, or only de-
vices will also be backed up automatically, whenever the data in a register is
changed and the receivers are updated. NOTE: Use ash drive formatting FAT16
or FAT32.
10.7 BACKUP
- ENGLISH -