62
By activating this function with the receivers, each activation performed by a
device (TX, CT, Active or Passive Tag) considers that only one vehicle may pass
through the sensor (inductive loop or photocell) installed near the door or ac-
cess barrier and connected to the Receiver. If another vehicle passes (ride), an
audible alert will be issued and the message “DOUBLE PASS” will be displayed
on the MG3000’s display, storing the event in the internal memory for later con-
sultations.
Enables or disables the audible alert, after any activation performed from any de-
vice or also by performing an operation on the MG3000 (available for activation
on the “OPTIONS 2/9” screen, in “ADVANCED MENU 1/2”).
If this function is activated, whenever a device is activated, the information will be
described on the MG3000’s display, and if there is an activation immediately after
the rst one, the described messages will be overwritten with the information of
the second drive.
The option “TIME GROUPS” enables the selection, during the registration pro-
cedure, of one of 15 user group options. These groups are pre-congured (in
the “ADVANCED MENU 2/2” in “GROUPS”) with the denition of the days of the
week and the time of entry and exit in which these users will be able to make
the access.
This conguration can be useful to control the access of employees or service
providers who do not have free access to the building, increasing security and
preventing users from having access outside the allowed days and hours.
The baud rate can be adjusted to 20kbps (lower rate for long cabling), as long as
the receivers can also be adjusted with the same parameters (see the receiver’s
manual).
11.6.3 DOUBLE PASS EVENT
11.6.4 BUZZER BEEPS
11.6.5 OVERWRITING DISPLAYED EVENTS
11.6.6 TIME GROUPS
Figure 11.6.6.a
- ENGLISH -
265